Skip to content
Contact

DALI · Interface guide

Device

The station's own settings. Identity and location, time, data storage, firmware updates, remote support, configuration backup and restart.

The Device page holds the settings that belong to the station itself rather than to a sensor or a connection. It has five tabs: General, Time, Storage, Firmware and System. Most sections are cards you can fold by clicking their heading.

Who can open it: Admin and Factory. Some cards are Factory only; the tables below say which.

General tab

CardWho sees it
Device InformationFactory
Location CoordinatesAdmin, Factory

Device Information (Factory)

Shows the station's USN (serial number), Part ID, Model, Hardware Version and Software Version, and the site fields below. Admins see these values on the Dashboard instead.

FieldAllowed valuesWhat it does
Station IDUp to 32 charactersYour own ID for the station, for example a site code.
Station NameUp to 40 charactersThe name shown on the Dashboard and in reports.
LocationUp to 60 charactersA description of the site.

The serial number, part number, model and hardware version are set by Aeron at the factory. Save stores the card.

Location Coordinates

The station's latitude and longitude. They are used by the sunrise, sunset and sun-position equations, by Reset to zero after sunset, and in the Modbus slave registers.

The top of the card shows the coordinates in use and where they come from: Live GPS fix, Last good GPS fix, Manual entry or No coordinates available.

ControlAllowed valuesWhat it does
ModeAutomatic (GPS) or ManualAutomatic uses the live GPS fix, and the last good fix if GPS drops. Manual uses the numbers you enter and ignores GPS.
Manual Latitude-90 to 90 (positive is north)Manual mode only.
Manual Longitude-180 to 180 (positive is east)Manual mode only.
Use as manualCopies the current GPS fix into the manual fields.

Save stores manual coordinates.

Time tab

Auto Time Sync

The station can set its clock from GPS, the cellular network or an internet time server (NTP), in the order you choose.

FieldAllowed valuesWhat it does
Sync Interval (Hours)1 to 24How often the station re-checks its clock.
NTP ServerA host name, up to 64 charactersThe internet time server, for example pool.ntp.org.
GPS Priority, Cellular Priority, NTP PriorityDisabled, 1, 2 or 3Which source is tried first. Disabled leaves a source out. Each number can be used once.
TimezoneSearch and pick from the listThe station's time zone. All times on the station follow it.
DST SettingAutomatic (follow daylight saving rules) or DisabledDisabled keeps the zone's standard offset all year.

A line under the fields shows the last automatic sync, or the last attempt if it failed.

ButtonWhat it does
SaveStores the sync settings and time zone.
Sync NowSyncs the clock straight away from the sources above.

Manual Time Override

Sets the clock once, by hand. Use it when no time source is available.

FieldAllowed valuesWhat it does
Date & TimeDD-MM-YYYY HH:MM:SS, 24-hour, year 1970 to 2037The time to set, in the station's time zone.
ButtonWhat it does
Apply Manual TimeSets the clock to the value entered.
Sync to Browser TimeSets the clock from your computer's clock in one step.

If automatic sync is on, the next sync may change the clock again.

Why the time matters

Logged data is stamped with the station's time, uploads are ordered by it, and sign-in with a Live3 access code only works when the station's clock is within a few minutes of the real time.

Storage tab

CardWho sees it
Data Storage Configuration, USB Export, SD CardAdmin, Factory
Storage DetailsAdmin, Factory

Data Storage Configuration

Processed Data is the logged data: one record per interval.

FieldAllowed valuesWhat it does
Update Interval1, 5, 10, 15, 30 or 60 minThe logging interval: how often a record is written.
Create Interval1, 3, 6 or 12 hours, 1 day or 1 monthHow often a new data file is started. Downloads are split the same way.

Raw Data is the per-second data.

FieldAllowed valuesWhat it does
Enable Raw Data LoggingOn or offWhether per-second data is kept at all.
Update Interval1, 2, 5, 10, 15 or 30 secHow often a raw record is written.
Create Interval1, 3, 6 or 12 hours, or 1 dayHow often a new raw file is started.

Save applies both sections.

Show stale sensor values as NaN (recommended) saves by itself. When on, a sensor that has stopped answering is recorded as NaN (no value) instead of repeating its last reading.

USB Export and SD Card

ControlWhat it does
Enable USB data exportAllows or blocks copying data to a USB drive plugged into the station.
Enable SD card slotAllows or blocks the SD card. Turning it off unmounts the card within about 15 seconds and keeps it unmounted until you turn it back on.

Storage Details

Shows how full the internal memory (eMMC) and the SD card are, and for each an estimate of how many days of data fit before the oldest data is removed ("about 120 days left"). Refresh reads the figures again.

ButtonWhat it does
Clear Internal MemoryDeletes all data files and logs from internal memory. The SD card is not touched. Asks you to confirm. Cannot be undone.
Clear SD CardDeletes all data files from the SD card. Internal memory is not touched. Asks you to confirm.
Format SD CardErases and reformats the SD card. Use it when the SD card banner reports a card error. Asks you to confirm.

Clearing is permanent

Data that has not been downloaded or uploaded yet is lost when you clear or format. Download what you need first on Data output.

Firmware tab

CardWho sees it
UpdatesAdmin, Factory
Firmware Upload, Firmware Update (Field Sensors)Factory

Updates

On firmware 4.1 and later. Firmware releases are chosen and assigned to a station in Live3. The station downloads the release, checks that it is signed by Aeron, and installs it. This card shows where the station stands.

StatusMeaning
Up to dateThe station is on its assigned version and has checked with Live3 in the last day.
Couldn't check for updatesThe station has not heard from Live3 recently.
Not connected to Live3, so newer updates are not known hereThe station has never checked.
Downloading (version)Shows how many of the release's parts have arrived.
(version) is ready to installDownloaded and verified. The line underneath says whether you can install it.
Installing (version)Some services restart while it installs.
Update failedThe station is still on its previous version. The reason is shown.

Notes under the status can say Paused in Live3, Installs in the next scheduled window, No update is assigned to this station, or An update is on the way but not ready yet.

ButtonWhat it does
Install nowInstalls a release that is ready. Shown only when installing is switched on for this station.
Check for updatesAsks Live3 now instead of waiting. The page waits up to 90 seconds for the answer; the station keeps checking on its own either way.

Below, the card lists the update policy, when the station last checked, when the current version was installed, and its parts.

See Firmware updates and Update firmware.

Firmware Upload and Firmware Update (Field Sensors)

Factory only. Aeron uses these to load signed firmware onto the station's coprocessor, and onto some supported field sensors connected over RS232 or RS485. The station refuses any package that is not signed by Aeron.

System tab

CardWho sees it
CPU TemperatureFactory
SeRAAdmin, Factory
Device TokenFactory
Import / Export ConfigurationFactory
System RebootAdmin, Factory

SeRA (remote support)

SeRA lets Aeron support reach this station's console for a limited time. See Remote support.

ShownWhat it is
StatusEnabled, Disabled, or Enabled, not connected when the station cannot reach the remote access service.
Session, RemainingWhether a session is open and how long it has left.
Access Link, Access PasswordWhile enabled: what to give Aeron support so they can connect.
ControlAllowed valuesWhat it does
Timeout5, 10, 15 or 30 min, 1, 2, 4, 8, 12 or 24 hoursHow long remote access stays open. It closes by itself at the end.
Enable SeRA / Disable SeRAOpens or closes remote access.

Device Token (Factory)

Shows whether the station holds its own Live3 credential: Token active, or No device token yet, in which case remote access and data sync cannot start. The token is fetched on the Commissioning page.

Import / Export Configuration (Factory)

ButtonWhat it does
Export ConfigurationDownloads the station's whole configuration as a ZIP file.
Generate Commissioning ReportMakes a PDF report of the station's setup.
Import SelectedImports the sections you tick from a configuration ZIP.

When you choose a ZIP to import, the page shows which station, model, date and firmware it came from, and warns you if the model differs from this station. Then tick the sections to import: Serial / Modbus, SDI-12, Channels and Parameters are ticked by default; Sensors, Cloud / Upload, Network, Time Sync, Device Location, Data Storage, Device Info and the rest start unticked, because they are more likely to overwrite settings that belong to this station. See Copy a configuration to another station.

System Reboot

Reboot Device restarts the station after you confirm. All connections drop. A restart usually takes about 90 seconds; the page counts the time and reconnects when the station is back.

Messages you may see

MessageWhat it means
Latitude must be between -90 and 90 / Longitude must be between -180 and 180Correct the coordinate.
Enter latitude and longitude before savingManual mode needs both values.
No GPS fix to copyUse as manual needs a GPS fix.
Year must be 1970 to 2037The station's clock cannot be set outside those years.
Use DD-MM-YYYY HH:MM:SS (24h, with seconds)The manual time is in the wrong format.
Invalid Processed Update Interval (and the other interval messages)Pick a value from the list.
Live3 didn't answer yet. The station keeps checking on its own.Check for updates timed out after 90 seconds.