Skip to content
Contact

Datasheet · Weather sensors

RIGEL2-MT-RS485 datasheet

Specifications, wiring and ordering information for the RIGEL2-MT-RS485.

Updated

Specifications for the RIGEL2-MT-RS485. What it is for and its key features are on its product page.

Temperature measurement

ParameterValue
Output signalRS485 Modbus RTU
Temperature sensing range−40 °C to +150 °C
AccuracyIEC 60751 Class A, ±(0.15 + 0.002|t|) °C ¹
Uncertainty±0.3 °C
Resolution0.01 °C
Sensor elementRTD PT1000 Class A

¹ |t| is the temperature in °C, ignoring its sign.

Electrical

ParameterValue
Supply voltage12 VDC / 24 VDC (power input rated +9 to +28 VDC)

Physical and environmental

ParameterValue
Operating temperature−40 °C to +80 °C (electronics)
Ingress protectionIP65
Material, sensing discAluminium 6082, anodised
Material, electronics housingABS
Sensing disc sizeØ 25.4 mm × 7.2 mm
Weight<20 g (excluding cable)
CableLi2YD11Y, 24 AWG, braided shield, extruded polyurethane insulation

The sensing disc reads up to +150 °C, but the electronics housing is rated to +80 °C, so mount the housing out of direct contact with the module.

Wiring

Wire colourFunction
RedPower input, +9 to +28 VDC
GreyPower ground
YellowRS485 + (A)
BlueRS485 − (B)
GreenChassis ground (earth)
WhiteReserved, leave unconnected
PinkReserved, leave unconnected
BrownReserved, leave unconnected

Connect the yellow and blue pair to the logger's RS485 port, terminate the bus at both ends as usual for RS485, and earth the green wire at one point only.

Ordering

RIGEL 2 MT-RS485, product code 55020. The other Rigel 2 models are the analog 4–20 mA MT-A420 (55009) and the PT1000 resistance MT-RTD1K (55006); see Rigel 2.

More information