Skip to content
Contact

Datasheet · Weather stations and soiling

Soiling Index Measurement System datasheet

Specifications and ordering information for the Soiling Index Measurement System.

Updated

Specifications for the Soiling Index Measurement System. What it is for and its key features are on its product page.

At a glance

ItemValue
StandardIEC 61724-1:2021 · Annex C
ProtectionIP65 · Dust + Water
Operating Range−40°C to +80°C
ConnectivityETH · Wi-Fi · LTE · Modbus
Time SyncGPS + Internet
Data OutputReal-Time SI + Daily Average
Models−01 System / −02 Complete Kit
OriginMade in India · v2.0.0 · Aug 2025

Soiling

ParameterValue
Panel WattageUp to 1200 W
Short-Circuit Current (Isc) Range0 – 20 A
Shunt Accuracy±0.05% FSD
Soiling Leveling Index Resolution0.01%

Electrical

ParameterValue
Voltage Input+9 to +28 V DC
Current Consumption12 V ≤ 85 mA

Temperature

ParameterValue
Sensor TypeRTD PT1000 Class A
Range−40°C to 150°C
AccuracyClass A: ±(0.15 + 0.0020 |t|) °C

Communication

ParameterValue
RS232 (1)NMEA Output / MODBUS Slave
RS232 (2)MODBUS Master
RS485 (1)MODBUS Master
RS485 (2)MODBUS Slave
Baudrate RS232/RS4859600 / 19200 / 38400 / 57600 / 115200 bps
Network InterfacesEthernet, Wi-Fi, LTE (4G)
Output Data FormatComma Separated Format (CSV)

Storage

ParameterValue
SD Card Memory8 GB (default), expandable to 32 GB
USBData retrieval on Pen Drive

Environment

ParameterValue
Operating Temperature−40 to +80°C
ProtectionIP65

Ordering information

ModelProduct code
ARN-SIMS100-0190001
ARN-SIMS100-0290063

More information

The PDF datasheet and a quote form are on the Soiling Index Measurement System product page at aeronsystems.com. For pricing or ordering, email sales@aeronsystems.com. For help with an installed unit, email support@aeronsystems.com.