Datasheet · Weather sensors
RIGEL 2 MT-RTD1K datasheet
Specifications and ordering information for the RIGEL 2 MT-RTD1K.
Updated
Specifications for the RIGEL 2 MT-RTD1K. What it is for and its key features are on its product page.
Product code: 55006
MT-A420
| Parameter | Value |
|---|---|
| Output Signal | 4 to 20 mA Current |
| Temperature Range | -40 C to +150 C |
| Accuracy | IEC 60751 Class A, ±(0.15 + 0.002|t|) °C |
| Uncertainty | +-0.3 deg |
| Resolution | 0.01 C |
| Sensor Element Type | RTD PT1000 Class A |
| Current Consumption | 0.5 mA |
| Operating Temperature | -40 C to +150 C |
| Ingress Protection | IP65 |
| Material | Aluminium 6082 |
| Dimensions | Dia. 25.4 mm x Thickness 7.2 mm |
| Weight | <15 g (excl. cable weight) |
| Cable Diameter | 0.216 cm (0.085 in.) |
| Cable Length | 2 meters |
MT-RTD1K
| Parameter | Value |
|---|---|
| Output Signal | Resistance Output (PT1000) |
| Temperature Range | -40 C to +150 C |
| Accuracy | IEC 60751 Class A, ±(0.15 + 0.002|t|) °C |
| Resolution | 0.001 C |
| Sensor Element Type | RTD PT1000 Class A |
| Operating Temperature | -40 C to +150 C |
| Ingress Protection | IP65 |
| Material | Aluminium 6082 |
| Dimensions | Dia. 25.4 mm x Thickness 7.2 mm |
| Weight | <15 g (excl. cable weight) |
| Cable Diameter | 0.216 cm (0.085 in.) |
| Cable Length | 2 meters |
MT-RS485
| Parameter | Value |
|---|---|
| Output Signal | RS485 MODBUS RTU |
| Temperature Sensing Range | -40 C to +150 C |
| Accuracy | IEC 60751 Class A, ±(0.15 + 0.002|t|) °C |
| Uncertainty | +-0.3 deg |
| Resolution | 0.01 C |
| Sensor Element Type | RTD PT1000 Class A |
| Supply Voltage | 12 VDC / 24 VDC |
| Operating Temperature | -40 C to +80 C |
| Ingress Protection | IP65 |
| Material (Sensing Element) | Aluminium 6082 |
| Material (Circuitry) | ABS |
| Dimensions (Sensing Element) | Dia. 25.4 mm x Thickness 7.2 mm |
| Weight | <20 g (excl. cable weight) |
| Cable Type | Li2YD11Y-24 AWG BRD |
| Cable Insulation | Extruded Polyurethane |
Specifications
| Parameter | Value |
|---|---|
| Output Signal | Resistance Output (PT1000) |
| Temperature Range | -40 C to +150 C |
| Accuracy | IEC 60751 Class A, ±(0.15 + 0.002|t|) °C |
| Resolution | 0.001 C |
| Sensor Element Type | RTD PT1000 Class A |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | -40 C to +150 C |
| Ingress Protection | IP65 |
| Material | Aluminium 6082 |
| Dimensions | Dia. 25.4 mm x Thickness 7.2 mm |
| Weight | <15 g (excl. cable weight) |
| Cable Diameter | 0.216 cm (0.085 in.) |
| Cable Length | 2 meters |
Ordering information
| Model | Product code | Description |
|---|---|---|
| RIGEL 2 MT-RTD1K | 55006 | PV module temperature sensor, PT1000 resistance output |
More information